EDI Supplier Documentation
Test Procedures
Testing the EDI connection
Data Communication Guide
This guide covers the direct connection to ArvinMeritor mailbox only.
Interchange Envelopes (ISA IEA GS GE)
Advance Ship Notice (856)
Application Advice (824)
Material Planning Release (830)
Price Synchronization (832)
Receipt Advice (861)

Advance Ship Notice / ASN (856)
Segment : DTM - Date / Time Reference

Mandatory/Optional: Mandatory

Purpose : To specify pertinent dates and times

Level : Heading

Max Usage/Loops : 10/None

General Info : One DTM segment in the heading area is mandatory to provide ship date & time information. The date and time should be provided in the shippers perspective.

Examples : DTM*011*900130*1200*ET N/L

Element ID Element Number Element Name AIAG Features ArvinMeritor Use Comments
DTM01 374 Date/Time Qualifier M ID 03/03 Yes "011" = Local date & time that shipment leaves the supplier. "017" will be ignored.
DTM02 373 Date M DT 06/06 Yes (YYMMDD)
DTM03 337 Time M TM 04/04 Yes (HHMM)
DTM04 623 Time Zone Qualifier M ID 02/02 Yes Valid time zones are:
"CD" = Central Daylight time
"CS" = Central Standard
"CT" = Central time
"ED" = Eastern time
"ES" = Eastern Standard time
"ET" = Eastern time
"GM" = Greenwich Standard time
"LT" = Local time
"MD" = Mountain time
"MS" = Mountain Standard time
"MT" = Mountain time
"PD" = Pacific time
"PS" = Pacific Standard time
"PT" = Pacific time