ISA - Interchange Control Header
ISA Segment

TRANSACTION SET: All Transactions (Interchange Control)

MAX USE/LOOPS: 1 per interchange/none

PURPOSE: To start and identify an interchange of one or more functional groups and interchange-related control segments.

GENERAL INFORMATION: The actual values of the data element separator and the data segment terminator for this interchange are set by the interchange control header. In the segment diagram below, the data element separator is represented by the "*" character, and the data segment terminator is represented by the "N/L" character. For a particular interchange, the value at the fourth character position is the data element separator, and the value of the last character position is the value of the data segment terminator. The extent of this particular usage of the data element separator and the data segment terminator is from this header to and including the next interchange trailer.

The interchange control number value in this header must match the value in the same data element in the corresponding interchange control trailer.

The first occurrence of the data element separator (byte 4) defines the actual value of the data element separator and is graphically displayed as an asterisk "*". The first occurrence of the segment terminator, 1 byte after the data element ISA16, defines the actual value of the data segment terminator and is graphically displayed as "N/L".

EXAMPLE:   ISA*00* *00* *01*202145445 *01*
062442561 *960421*1550*U*00200*000000001*0*P* N/L
Element ID Element Number   Element Name   Features  Comments
ISA0 744 Authorize Info Qualifier M ID 02/02 Use "00"
ISA02 745 Authorize Info M AN 10/10 Use ten spaces
ISA03 746 Security Info. Qualifier M ID 02/02 Use "00" for no password
ISA04 747 Security Info. M AN 10/10 Use ten spaces
ISA05 704 Interchange ID Qualifier M ID 02/02 Use "01", "12", or "ZZ"
ISA06 705 Interchange Sender ID M ID 15/15 DUNS number if ISA05="01".
Left justify, space fill.
ISA07 704 Interchange ID Qualifier M ID 02/02 Use "01".
ISA08 706 Interchange Receiver ID M ID 15/15 ArvinMeritor DUNS number "006414361".
ISA09 373 Date M DT 06/06 Date of creation (YYMMDD).
ISA10 337 Time M TM 04/04 Time of creation (HHMM).
ISA11 726 Interchange Standards ID M ID 01/01 Use "U" for USA.
ISA12 703 Interchange Version ID M ID 05/05 Use "00200".
ISA13 709 Interchange Control Number M NO 09/09 Sequential number starting with 000000001 and incremented by 1 for each subsequent ISA between sender and receiver.
ISA14 749 Acknowledge M ID 01/01 Use "0" for no Ack. Req.
ISA15 748 Test Indicator M ID 01/01 Use "T" for test data and "P" for production data.
ISA16 701 Sub-element Separator M AN 01/01 Use "*".